Summary
Resources
The NT920WA is a time based alarm unit with built in Power Fail detection which is most often used in conjunction with Navitron Autopilots but may also be used as a stand alone alarm system remotely activated by proprietary autopilot systems (11 – 40Vdc supply voltage range).
Unsuitable for external location, the Watch Alarm should be installed in an enclosed bridge or wheelhouse in a position commensurate with RESET button operation.
At the instant of autopilot engagement (Mode switch to ON) a four minute timing period commences which may be restarted at any time by manual operation of the Watch Alarm RESET button.
If the RESET button is not pushed and the four minute period expires, a low level audible alarm is emitted for a period of one minute (60 seconds).
Failure to cancel the low level alarm within 60 seconds will result in a high level audible alarm which will continue until the RESET button is operated (new four minute period starts) or until the autopilot is disengaged (Mode switch to STANDBY or OFF).
A two way built in POWER FAIL alarm will immediately sound at the emergency high level in the event of autopilot power supply or watch alarm internal battery failure.
The POWER FAIL alarm can only be reset by disengagement of the autopilot or restoration of the power supply.
A volt free normally open contact rated 1A / 24Vdc is provided within the Watch Alarm to drive an auxiliary alarm (if required) in the high level (emergency) mode only.
Compass Safe Distance – 1.0m
Weight – 1.0Kg
© 2023 Navitron Systems Limited | Registered in England No. 2607869